The Manual Injector is a manual syringe driver for pneumatic or hydraulic control of injection needles or holding pipettes. It is suitable for injecting volumes in the nanoliter to microliter range. It is also widely used as a fluid control device for applications requiring sensitive manual control of the displacement of microneedle contents. The system is constructed from the highest quality parts. The base assembly is black anodized aluminum. A non-rotating Mitutoyo micrometer provides the drive to the gas-tight syringe1. A precision 3-way valve provides a convenient method for filling the fluid line and clearing air bubbles from the line. Teflon tubing, chromatography connectors and a pipette holder complete the system.

The injection resolution is dependent on the volume of the syringe that is installed, as outlined in the table below. For example, with a 25µl syringe installed, one complete rotation of the micrometer (25 divisions) yields a displacement equivalent to a volume of 267nl and turning the micrometer one division (0.001in) yields 10.6nl.

Syringe
Volume
Volume Per
Revolution
Volume Per
Division
10µl
106nl
4.2nl
25µl
267nl
10.6nl
50µl
529nl
21.2nl
100µl
1.06µl
42.3nl
250µl
2.65µl
105.8nl
500µl
5.29µl
211.7nl
1000µl
10.58µl
423.4nl

 Please specify the syringe volume that you will be using
2 Unless specified otherwise, a pipette holder for 1mm outside diameter glass will be supplied. The diameter of the pipette holder is 0.25in / 6.4mm. For micromanipulators that connot accept this size holder an adapter is optionally available. Please contact Sutter for further information.

      $687.05

      Original: $1,963.00

      -65%
      Sutter Manual Microinjector—

      $1,963.00

      $687.05

      Product Information

      Shipping & Returns

      Description

      The Manual Injector is a manual syringe driver for pneumatic or hydraulic control of injection needles or holding pipettes. It is suitable for injecting volumes in the nanoliter to microliter range. It is also widely used as a fluid control device for applications requiring sensitive manual control of the displacement of microneedle contents. The system is constructed from the highest quality parts. The base assembly is black anodized aluminum. A non-rotating Mitutoyo micrometer provides the drive to the gas-tight syringe1. A precision 3-way valve provides a convenient method for filling the fluid line and clearing air bubbles from the line. Teflon tubing, chromatography connectors and a pipette holder complete the system.

      The injection resolution is dependent on the volume of the syringe that is installed, as outlined in the table below. For example, with a 25µl syringe installed, one complete rotation of the micrometer (25 divisions) yields a displacement equivalent to a volume of 267nl and turning the micrometer one division (0.001in) yields 10.6nl.

      Syringe
      Volume
      Volume Per
      Revolution
      Volume Per
      Division
      10µl
      106nl
      4.2nl
      25µl
      267nl
      10.6nl
      50µl
      529nl
      21.2nl
      100µl
      1.06µl
      42.3nl
      250µl
      2.65µl
      105.8nl
      500µl
      5.29µl
      211.7nl
      1000µl
      10.58µl
      423.4nl

       Please specify the syringe volume that you will be using
      2 Unless specified otherwise, a pipette holder for 1mm outside diameter glass will be supplied. The diameter of the pipette holder is 0.25in / 6.4mm. For micromanipulators that connot accept this size holder an adapter is optionally available. Please contact Sutter for further information.