These laboratory refrigerators are designed for reliable and cost-effective cold storage. This model features ultra-low energy consumption and energy efficient natural refrigerants. Using microprocessor temperature technology, this unit delivers precise temperature monitoring and control. It offers essential security features, including keyed door locks and temperature alarms, along with remote alarm contacts. Enjoy durable powder-coated steel construction, glass door transparency, and adjustable inner shelving to optimize your workflow. All features are designed to heighten performance and efficiency in your lab.

Description

Maximum temperature variation (Cabinet air) +/- 2.5° C
Stability (Simulator ballast) +/- 0.5° C
Energy Consumption (kWh/day) <2.8 KWh/day  *meets ENERGY STAR® v2.0 for Laboratory Refrigerators
Average Heat Rejection (BTU/hr) <720 BTU/h
Pull down time to nominal operating temp < 60 min (empty)
Noise Pressure Level (dBA) 40 dBA or less installed
Compressor Hermetic
Refrigerant EPA SNAP compliant R600a Isobutane (Hydrocarbon natural refrigerant)
Condenser Tube and grid, high efficiency fan forced air
Evaporator Fin and tube, high efficiency fan forced air
Defrost Cycle Defrost
Performance Notes Max temperature variation based on an empty chamber at steady state using 15 bare (unweighted) thermocouple probes.  Product loading, door openings, and ambient conditions will affect performance.  Stability of simulator ballast based on bottle probe provided with the unit located center of empty chamber at steady state, no door openings

Performance

Maximum temperature variation (Cabinet air) +/- 1.5° C
Stability (Simulator ballast) +/- 0.3° C
Energy Consumption (kWh/day) <2.2 KWh/day  *meets ENERGY STAR® v2.0 for Laboratory Refrigerators
Average Heat Rejection (BTU/hr) <570 BTU/h
Pull down time to nominal operating temp < 40 min (empty)
Noise Pressure Level (dBA) 40 dBA or less installed
Compressor Hermetic, variable speed
Refrigerant EPA SNAP compliant R600a Isobutane (Hydrocarbon natural refrigerant)
Condenser Tube and grid, high efficiency fan forced air
Evaporator Fin and tube, high efficiency fan forced air
Defrost Cycle Defrost
Performance Notes Max temperature variation based on an empty chamber at steady state using 15 bare (unweighted) thermocouple probes.  Product loading, door openings, and ambient conditions will affect performance.  Stability of simulator ballast based on bottle probe provided with the unit located center of empty chamber at steady state, no door openings

Temp Controller

Controller technology Microprocessor temperature controller with variable frequency compressor control, C°/F° switchable, resolution is 0.1° C/0.2° F
Battery Backup Non-applicable
Display technology Digital temperature display
Adjustable Temperature Range 2° C to 15° C
Digital Communication Non-applicable
External alarm connection Remote alarm contacts
Alarms Audible and visual high/low temperature alarms, remote alarm contacts
Display Probe Product simulator bottle with glass bead media
Disclaimers Refrigerator requires a minimum 2” of clearance around back and sides of the unit for proper ventilation (more if next to heat rejecting equipment) – improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure

 

Product Documents

$5,689.20
ABS 72 Cu. Ft. Standard Glass Door Laboratory Refrigerator ABT-VS-LS-72
$5,689.20

Product Information

Shipping & Returns

Description

ABS 72 Cu. Ft. Standard Glass Door Laboratory Refrigerator ABT-VS-LS-72

These laboratory refrigerators are designed for reliable and cost-effective cold storage. This model features ultra-low energy consumption and energy efficient natural refrigerants. Using microprocessor temperature technology, this unit delivers precise temperature monitoring and control. It offers essential security features, including keyed door locks and temperature alarms, along with remote alarm contacts. Enjoy durable powder-coated steel construction, glass door transparency, and adjustable inner shelving to optimize your workflow. All features are designed to heighten performance and efficiency in your lab.

Description

Maximum temperature variation (Cabinet air) +/- 2.5° C
Stability (Simulator ballast) +/- 0.5° C
Energy Consumption (kWh/day) <2.8 KWh/day  *meets ENERGY STAR® v2.0 for Laboratory Refrigerators
Average Heat Rejection (BTU/hr) <720 BTU/h
Pull down time to nominal operating temp < 60 min (empty)
Noise Pressure Level (dBA) 40 dBA or less installed
Compressor Hermetic
Refrigerant EPA SNAP compliant R600a Isobutane (Hydrocarbon natural refrigerant)
Condenser Tube and grid, high efficiency fan forced air
Evaporator Fin and tube, high efficiency fan forced air
Defrost Cycle Defrost
Performance Notes Max temperature variation based on an empty chamber at steady state using 15 bare (unweighted) thermocouple probes.  Product loading, door openings, and ambient conditions will affect performance.  Stability of simulator ballast based on bottle probe provided with the unit located center of empty chamber at steady state, no door openings

Performance

Maximum temperature variation (Cabinet air) +/- 1.5° C
Stability (Simulator ballast) +/- 0.3° C
Energy Consumption (kWh/day) <2.2 KWh/day  *meets ENERGY STAR® v2.0 for Laboratory Refrigerators
Average Heat Rejection (BTU/hr) <570 BTU/h
Pull down time to nominal operating temp < 40 min (empty)
Noise Pressure Level (dBA) 40 dBA or less installed
Compressor Hermetic, variable speed
Refrigerant EPA SNAP compliant R600a Isobutane (Hydrocarbon natural refrigerant)
Condenser Tube and grid, high efficiency fan forced air
Evaporator Fin and tube, high efficiency fan forced air
Defrost Cycle Defrost
Performance Notes Max temperature variation based on an empty chamber at steady state using 15 bare (unweighted) thermocouple probes.  Product loading, door openings, and ambient conditions will affect performance.  Stability of simulator ballast based on bottle probe provided with the unit located center of empty chamber at steady state, no door openings

Temp Controller

Controller technology Microprocessor temperature controller with variable frequency compressor control, C°/F° switchable, resolution is 0.1° C/0.2° F
Battery Backup Non-applicable
Display technology Digital temperature display
Adjustable Temperature Range 2° C to 15° C
Digital Communication Non-applicable
External alarm connection Remote alarm contacts
Alarms Audible and visual high/low temperature alarms, remote alarm contacts
Display Probe Product simulator bottle with glass bead media
Disclaimers Refrigerator requires a minimum 2” of clearance around back and sides of the unit for proper ventilation (more if next to heat rejecting equipment) – improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure

 