ABS 30 Cu Ft TempLog Premier Touchscreen Manual Defrost Laboratory Freezer -30C ABT-HC-MFP-3030-TS

ABS 30 Cu Ft TempLog Premier Touchscreen Manual Defrost Laboratory Freezer -30C ABT-HC-MFP-3030-TS
ABS 30 Cu Ft TempLog Premier Touchscreen Manual Defrost Laboratory Freezer -30C ABT-HC-MFP-3030-TS
This premier manual defrost touchscreen freezer redefines precision and user experience for critical sample storage. These models offer exceptional temperature uniformity and extensive data logging and charting capabilities for auditing and compliance. Access a 24-hour temperature chart and data logging capabilities through an intuitive touchscreen interface. Experience an extensive array of customizable audible and visual alarms supported by battery backup and remote alarm contacts. These units utilize microprocessor temperature technology, protecting samples down to -33°C. They also feature natural hydrocarbon refrigerants for EPA SNAP compliance and eco-friendly cooling. This freezer provides an energy-efficient and high-performance solution for any laboratory needing precise temperature control and data logging capabilities.
Description
| Storage capacity (cu. ft) | 30 Cu. Ft. |
| Door | One (1) solid swing, right hinged; stainless steel door handle; magnetic door gasket |
| Interior | Five (5) inner fast-freeze compartments with doors for temperature maintenance |
| Shelves | Four (4) fixed evaporator shelves |
| Mounting and Installation | Caster platform |
| External probe access | 3/4ā³ probe access port on rear wall |
| Insulation | EPA compliant high density urethane foam |
| Exterior materials | Powder coated steel |
| Access control | Keyed door lock |
| General warranty | Two (2) year parts and labor warranty |
| Compressor warranty | Five (5) year compressor parts warranty |
| Product Weight (lbs) | 330 |
| Shipping Weight (lbs) | 330 |
| Rated Amperage | 3.3 Amps |
| Power Plug/Power Cord | NEMA 5-15P plug, 6 ft long cord |
| Facility Electrical Requirement | 110 ā 120V AC, 15A breaker, NEMA 5-15 receptacle |
| Agency Listing and Certification | UL listed per UL 60335-1 and UL 60335-2-89 standards; c UL listed per CSA C22.2 No. 120 standard. |
Performance
| Uniformity (Cabinet air) | +/- 2.5°C |
| Stability (Cabinet air) | +/- 3.5°C |
| Maximum temperature variation (Cabinet air) | 7.5°C Total |
| Energy Consumption (kWh/day) | 7.7 kWh/day |
| Average Heat Rejection (BTU/hr) | 1100 BTU/hr |
| Pull down time to nominal operating temp | 120 min (empty) |
| Compressor | Hermetic, variable speed |
| Refrigerant | EPA SNAP compliant R290 propane |
| Condenser | Static ā exterior walls of cabinet with auxiliary fan |
| Evaporator | Evaporator shelves |
| Defrost | Manual defrost |
Temp Controller
| Controller technology | Microprocessor temperature controller with variable frequency compressor control |
| Battery Backup | Temperature display and alarm only (no active cooling) |
| Display technology | Touch screen digital temperature display with user friendly interface, real-time operational display clock, active temperature scale bar display, resettable 1-point min/max history, digital 24- hour temperature chart, and temperature data logging |
| Adjustable Temperature Range | -27° C to -33° C |
| External alarm connection | Remote alarm contacts |
| Alarms | Audible and visual high and low temperature alarms, remote alarm contacts, sensor error alarm, power failure alarm, resettable 1-point min/max history, alarm validation (audible, visual, and remote alarm), alarm mute with ring back, and customizable alarm time delay settings |
| Display Probe | Product simulator bottle with glass bead media |
| Disclaimers | Defrosting of the unit will need to be performed periodically to prevent severe ice build-up. Indoor use only, +18° C to +26° C (+65° F to +78° F), <70% RH Specifications are subject to change. Equipment requires 4ā of clearance around back and sides of the unit for proper ventilation ā improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure. Performance claims are based on testing at 22°C ambient using unbuffered air temperatures in an empty freezer at steady state operation. Performance may vary with environmental conditions, product load, or door openings. |
Ā
Original: $11,271.60
-65%$11,271.60
$3,945.06Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
ABS 30 Cu Ft TempLog Premier Touchscreen Manual Defrost Laboratory Freezer -30C ABT-HC-MFP-3030-TS
This premier manual defrost touchscreen freezer redefines precision and user experience for critical sample storage. These models offer exceptional temperature uniformity and extensive data logging and charting capabilities for auditing and compliance. Access a 24-hour temperature chart and data logging capabilities through an intuitive touchscreen interface. Experience an extensive array of customizable audible and visual alarms supported by battery backup and remote alarm contacts. These units utilize microprocessor temperature technology, protecting samples down to -33°C. They also feature natural hydrocarbon refrigerants for EPA SNAP compliance and eco-friendly cooling. This freezer provides an energy-efficient and high-performance solution for any laboratory needing precise temperature control and data logging capabilities.
Description
| Storage capacity (cu. ft) | 30 Cu. Ft. |
| Door | One (1) solid swing, right hinged; stainless steel door handle; magnetic door gasket |
| Interior | Five (5) inner fast-freeze compartments with doors for temperature maintenance |
| Shelves | Four (4) fixed evaporator shelves |
| Mounting and Installation | Caster platform |
| External probe access | 3/4ā³ probe access port on rear wall |
| Insulation | EPA compliant high density urethane foam |
| Exterior materials | Powder coated steel |
| Access control | Keyed door lock |
| General warranty | Two (2) year parts and labor warranty |
| Compressor warranty | Five (5) year compressor parts warranty |
| Product Weight (lbs) | 330 |
| Shipping Weight (lbs) | 330 |
| Rated Amperage | 3.3 Amps |
| Power Plug/Power Cord | NEMA 5-15P plug, 6 ft long cord |
| Facility Electrical Requirement | 110 ā 120V AC, 15A breaker, NEMA 5-15 receptacle |
| Agency Listing and Certification | UL listed per UL 60335-1 and UL 60335-2-89 standards; c UL listed per CSA C22.2 No. 120 standard. |
Performance
| Uniformity (Cabinet air) | +/- 2.5°C |
| Stability (Cabinet air) | +/- 3.5°C |
| Maximum temperature variation (Cabinet air) | 7.5°C Total |
| Energy Consumption (kWh/day) | 7.7 kWh/day |
| Average Heat Rejection (BTU/hr) | 1100 BTU/hr |
| Pull down time to nominal operating temp | 120 min (empty) |
| Compressor | Hermetic, variable speed |
| Refrigerant | EPA SNAP compliant R290 propane |
| Condenser | Static ā exterior walls of cabinet with auxiliary fan |
| Evaporator | Evaporator shelves |
| Defrost | Manual defrost |
Temp Controller
| Controller technology | Microprocessor temperature controller with variable frequency compressor control |
| Battery Backup | Temperature display and alarm only (no active cooling) |
| Display technology | Touch screen digital temperature display with user friendly interface, real-time operational display clock, active temperature scale bar display, resettable 1-point min/max history, digital 24- hour temperature chart, and temperature data logging |
| Adjustable Temperature Range | -27° C to -33° C |
| External alarm connection | Remote alarm contacts |
| Alarms | Audible and visual high and low temperature alarms, remote alarm contacts, sensor error alarm, power failure alarm, resettable 1-point min/max history, alarm validation (audible, visual, and remote alarm), alarm mute with ring back, and customizable alarm time delay settings |
| Display Probe | Product simulator bottle with glass bead media |
| Disclaimers | Defrosting of the unit will need to be performed periodically to prevent severe ice build-up. Indoor use only, +18° C to +26° C (+65° F to +78° F), <70% RH Specifications are subject to change. Equipment requires 4ā of clearance around back and sides of the unit for proper ventilation ā improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure. Performance claims are based on testing at 22°C ambient using unbuffered air temperatures in an empty freezer at steady state operation. Performance may vary with environmental conditions, product load, or door openings. |
Ā