ABS 30 cu. ft. Capacity Premier Laboratory Refrigerator Solid Door ABT-HC-30R-P
ABS 30 cu. ft. Capacity Premier Laboratory Refrigerator Solid Door ABT-HC-30R-P
Designed for reliable and eco-conscious laboratory storage, this 30 cu. ft. touchpad laboratory refrigerator offers versatile performance for lab environments. Its temperature control is powered by microprocessor technology and maintains tight temperature uniformity with an adjustable operating range of 2°C to 10°C. Enjoy a user-friendly touchpad controller and a robust alarm system including audible and visual temperature alarms, door ajar alarms, sensor error alarms, and power failure alarmsāall with battery backups to keep alarms running during outages. Utilizing hydrocarbon refrigerants, this unit meets EPA SNAP compliance, protecting environmental safety. It features a durable white powder-coated steel exterior, with a keyed door lock for added security. This unit offers 30 cubic feet of spacious storage and five adjustable shelves for versatile organization. With a low energy consumption and environmental benefits, the ABT-HC-30R-P is an efficient and next-level solution for diverse laboratory applications.
Details
| Storage capacity (cu. ft) | 30 Cu. Ft. |
| Door | One solid swing, right hinged; stainless steel door handle; magnetic door gasket |
| Shelves | Five adjustable |
| Drawers | Non-applicable |
| Mounting and Installation | Caster platform |
| Interior lighting | Non-applicable |
| Airflow Management | Forced draft circulation |
| External probe access | 3/4ā³ probe access port on rear wall |
| Insulation | EPA compliant high density urethane foam |
| Exterior materials | Powder coated steel |
| Access control | Keyed Door Lock |
| General warranty | Two (2) year parts and labor warranty |
| Compressor warranty | Five (5) year compressor parts warranty |
| Product Weight (lbs) | 350 |
| Shipping Weight (lbs) | 380 |
| Rated Amperage | 3.1 Amps |
| Power Plug/Power Cord | NEMA 5-15P plug, 6 ft long cord |
| Facility Electrical Requirement | 110 ā 120V AC, 15A breaker, NEMA 5-15 receptacle |
| Agency Listing and Certification | UL listed per UL 60335-1 and UL 60335-2-89 standards; c UL listed per CSA C22.2 No. 120 standard |
Performance
| Uniformity (Cabinet air) | +/- 1.6°C | |
| Stability (Cabinet air) | +/- 1.0°C | |
| Maximum temperature variation | 3.6 °C Total | |
| (Cabinet air) | ||
| Energy Consumption (KWh/day) | < 1.7 KWh/day | |
| Average Heat Rejection (BTU/hr) | 520 BUT/hr | |
| Pull down time to nominal operating temp |
|
|
| Width (in.) | 35.75ā³ | |
| Depth (in.) | 35.5ā³ | |
| Height (in.) | 76.5ā³ | |
| Refrigerant | EPA SNAP compliant R600a Isobutane |
Temp Controller
| Controller technology | Microprocessor temperature controller with variable frequency compressor control |
| Battery Backup | Temperature display and alarm only (no active cooling) |
| Display technology | Digital Temperature Display, Sample simulated digital temperature display; .1° Resolution |
| Digital Communication | Non-applicable |
| Data Transfer | Non-applicable |
| Temperature Setpoint Range Notes | Minimum temperature limited to avoid freezing |
| Adjustable Temperature Range | 2°C to 10°C |
| External alarm connection | Remote alarm contacts |
| Alarms | Audible and visual high and low temperature alarms, Remote alarm contacts, Sensor error alarm, Power failure alarm, Resettable 1-point Min/Max History, Alarm validation (audible, visual, and remote alarm), Alarm mute with ring back |
| Display Probe | Product simulator bottle with glass bead media |
| Disclaimers | Refrigerator requires a minimum 4ā of clearance around back and sides of the unit for proper ventilation (more if next to heat rejecting equipment) ā improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure |
Ā
Product Documents
Original: $6,349.20
-65%$6,349.20
$2,222.22Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
ABS 30 cu. ft. Capacity Premier Laboratory Refrigerator Solid Door ABT-HC-30R-P
Designed for reliable and eco-conscious laboratory storage, this 30 cu. ft. touchpad laboratory refrigerator offers versatile performance for lab environments. Its temperature control is powered by microprocessor technology and maintains tight temperature uniformity with an adjustable operating range of 2°C to 10°C. Enjoy a user-friendly touchpad controller and a robust alarm system including audible and visual temperature alarms, door ajar alarms, sensor error alarms, and power failure alarmsāall with battery backups to keep alarms running during outages. Utilizing hydrocarbon refrigerants, this unit meets EPA SNAP compliance, protecting environmental safety. It features a durable white powder-coated steel exterior, with a keyed door lock for added security. This unit offers 30 cubic feet of spacious storage and five adjustable shelves for versatile organization. With a low energy consumption and environmental benefits, the ABT-HC-30R-P is an efficient and next-level solution for diverse laboratory applications.
Details
| Storage capacity (cu. ft) | 30 Cu. Ft. |
| Door | One solid swing, right hinged; stainless steel door handle; magnetic door gasket |
| Shelves | Five adjustable |
| Drawers | Non-applicable |
| Mounting and Installation | Caster platform |
| Interior lighting | Non-applicable |
| Airflow Management | Forced draft circulation |
| External probe access | 3/4ā³ probe access port on rear wall |
| Insulation | EPA compliant high density urethane foam |
| Exterior materials | Powder coated steel |
| Access control | Keyed Door Lock |
| General warranty | Two (2) year parts and labor warranty |
| Compressor warranty | Five (5) year compressor parts warranty |
| Product Weight (lbs) | 350 |
| Shipping Weight (lbs) | 380 |
| Rated Amperage | 3.1 Amps |
| Power Plug/Power Cord | NEMA 5-15P plug, 6 ft long cord |
| Facility Electrical Requirement | 110 ā 120V AC, 15A breaker, NEMA 5-15 receptacle |
| Agency Listing and Certification | UL listed per UL 60335-1 and UL 60335-2-89 standards; c UL listed per CSA C22.2 No. 120 standard |
Performance
| Uniformity (Cabinet air) | +/- 1.6°C | |
| Stability (Cabinet air) | +/- 1.0°C | |
| Maximum temperature variation | 3.6 °C Total | |
| (Cabinet air) | ||
| Energy Consumption (KWh/day) | < 1.7 KWh/day | |
| Average Heat Rejection (BTU/hr) | 520 BUT/hr | |
| Pull down time to nominal operating temp |
|
|
| Width (in.) | 35.75ā³ | |
| Depth (in.) | 35.5ā³ | |
| Height (in.) | 76.5ā³ | |
| Refrigerant | EPA SNAP compliant R600a Isobutane |
Temp Controller
| Controller technology | Microprocessor temperature controller with variable frequency compressor control |
| Battery Backup | Temperature display and alarm only (no active cooling) |
| Display technology | Digital Temperature Display, Sample simulated digital temperature display; .1° Resolution |
| Digital Communication | Non-applicable |
| Data Transfer | Non-applicable |
| Temperature Setpoint Range Notes | Minimum temperature limited to avoid freezing |
| Adjustable Temperature Range | 2°C to 10°C |
| External alarm connection | Remote alarm contacts |
| Alarms | Audible and visual high and low temperature alarms, Remote alarm contacts, Sensor error alarm, Power failure alarm, Resettable 1-point Min/Max History, Alarm validation (audible, visual, and remote alarm), Alarm mute with ring back |
| Display Probe | Product simulator bottle with glass bead media |
| Disclaimers | Refrigerator requires a minimum 4ā of clearance around back and sides of the unit for proper ventilation (more if next to heat rejecting equipment) ā improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure |
Ā