ABS 23 Cu. Ft. Premier Glass Door Pharmacy Refrigerator PH-ABT-VS-23G
ABS 23 Cu. Ft. Premier Glass Door Pharmacy Refrigerator PH-ABT-VS-23G
Protect your valuable pharmaceuticals with the PH-ABT-VS-23G premier pharmacy refrigerator, engineered to maintain medications at optimal 2°C to 8°C temperatures with unmatched precision. This 23 cubic foot unit combines variable speed technology with natural R600a refrigerant to deliver exceptional energy efficiency under 1.2 KWh/day while meeting ENERGY STAR® v2.0 standards. The result is significant cost savings on your utility bills while maintaining the highest standards of medication storage safety.
Your pharmacy operations benefit from the PH-ABT-VS-23G’s intelligent design featuring a microprocessor controller with comprehensive alarm systems that safeguard against temperature excursions. The digital display allows easy monitoring while remote alarm contacts enable integration with your facility’s monitoring systems for 24/7 protection. With audible and visual alarms for high/low temperature, door ajar, power failure, and sensor errors, you’ll have complete confidence in your cold chain integrity.
Designed for real-world pharmacy environments, the PH-ABT-VS-23G features durable powder coated steel construction with high-density urethane foam insulation and a self-closing glass door that maintains consistent temperatures even during frequent access. The six adjustable shelves accommodate various medication sizes while swivel casters with locking front wheels allow easy cleaning and repositioning. Safety-shielded LED lighting illuminates contents clearly, and the included pharmacy toolkit provides everything needed for optimal operation. With a 2-year comprehensive warranty and 7-year compressor coverage, the PH-ABT-VS-23G delivers reliable performance you can count on.
Key Features
• 23 cubic foot capacity optimized for pharmacy storage needs
• Maintains 2°C to 8°C with ±0.3°C stability using simulator probe
• Variable speed compressor with eco-friendly R600a refrigerant
• Digital microprocessor controller with remote alarm contacts
• ENERGY STAR® v2.0 qualified with under 1.2 KWh/day consumption
• ETL and C-ETL listed for safety and performance assurance
Benefits
• Reduce energy costs significantly with industry-leading efficiency under 1.2 KWh/day
• Ensure medication safety with precise ±1.5°C temperature control throughout cabinet
• Minimize disruption with whisper-quiet 40 dBA operation in patient care areas
• Maximize storage flexibility using six shelves adjustable in half-inch increments
• Protect inventory 24/7 with comprehensive alarms and remote monitoring capability
• Save space with compact 26.875″ width while maintaining 23 cubic feet capacity
• Enjoy peace of mind with 7-year compressor warranty backing your investment
• Maintain compliance easily with included NIST traceable calibration certificate
Description
| Storage capacity (cu. ft) | 23 Cu. Ft. |
| Door | One (1) swing glass door, self-closing, right hinged, not reversible, magnetic door gasket |
| Shelves | Six (6) adjustable shelves (adjustable in ½” increments) |
| Mounting and Installation | Swivel casters – locking front casters |
| External probe access | 3/4″ probe access port on rear wall |
| Insulation | Cabinet is foamed-in-place with EPA compliant high-density urethane foam |
| Interior lighting | LED interior lights are safety shielded and switch controlled |
| Airflow Management | Forced draft air circulation, patented air flow technology |
| Exterior materials | Cabinet is foamed-in-place with EPA compliant high-density urethane foam |
| Access control | Keyed door lock; compatible with optional digital lock (Pyxis, Omnicell, and AcuDose RX) |
| General warranty | Two (2) year parts and labor warranty |
| Compressor warranty | Seven (7) year compressor warranty |
| Product Weight (lbs) | 274 |
| Shipping Weight (lbs) | 327 |
| Rated Amperage | 3 Amps |
| Power Plug/Power Cord | NEMA 5-15 plug, vaccine storage power cord warning label |
| Facility Electrical Requirement | 110 – 120V AC, 15A breaker, NEMA 5-15 receptacle |
| Agency Listing and Certification | ETL, C-ETL listed. Meets or exceeds ENERGY STAR® v2.0 for Laboratory Refrigerators. Official listing pending – see energystar.gov |
Performance
| Maximum temperature variation (Cabinet air) | +/- 1.5° C |
| Stability (Cabinet air) | +/- 0.3° C |
| Energy Consumption (kWh/day) | <1.2 KWh/day *meets ENERGY STAR® v2.0 for Laboratory Refrigerators |
| Average Heat Rejection (BTU/hr) | <320 BTU/h |
| Pull down time to nominal operating temp | < 35 min (empty) |
| Noise Pressure Level (dBA) | 40 dBA or less installed |
| Compressor | Hermetic, variable speed |
| Refrigerant | EPA SNAP compliant R600a Isobutane (Hydrocarbon natural refrigerant) |
| Condenser | Tube and grid, high efficiency fan forced air |
| Evaporator | Fin and tube, high efficiency fan forced air |
| Defrost | Cycle Defrost |
| Performance Notes | Max temperature variation based on an empty chamber at steady state using 15 bare (unweighted) thermocouple probes. Product loading, door openings, and ambient conditions will affect performance. Stability of simulator ballast based on bottle probe provided with the unit located center of empty chamber at steady state, no door openings |
Temp Controller
| Controller technology | Microprocessor with color touchscreen (8in) input and display, C°/F° switchable, resolution is 0.1° C/0.2° F |
| Battery Backup | For controller temperature display and alarms only, no cooling active |
| Display technology | Digital temperature display |
| Adjustable Temperature Range | 36°F to 46°F (2°C to 8°C) Calibrated using a NIST traceable device, certificate included |
| Digital Communication | Non-applicable |
| External alarm connection | Remote alarm contacts |
| Alarms | Audible and visual high/low temperature alarms, remote alarm contacts, sensor error alarm, power failure alarm, door ajar alarm |
| Display Probe | Product simulator bottle with glass bead media |
| Included Accessories | Pharmacy refrigerator/freezer toolkit |
| Disclaimers | Refrigerator requires a minimum 2” of clearance around back and sides of the unit for proper ventilation (more if next to heat rejecting equipment) – improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure |
Product Documents
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
ABS 23 Cu. Ft. Premier Glass Door Pharmacy Refrigerator PH-ABT-VS-23G
Protect your valuable pharmaceuticals with the PH-ABT-VS-23G premier pharmacy refrigerator, engineered to maintain medications at optimal 2°C to 8°C temperatures with unmatched precision. This 23 cubic foot unit combines variable speed technology with natural R600a refrigerant to deliver exceptional energy efficiency under 1.2 KWh/day while meeting ENERGY STAR® v2.0 standards. The result is significant cost savings on your utility bills while maintaining the highest standards of medication storage safety.
Your pharmacy operations benefit from the PH-ABT-VS-23G’s intelligent design featuring a microprocessor controller with comprehensive alarm systems that safeguard against temperature excursions. The digital display allows easy monitoring while remote alarm contacts enable integration with your facility’s monitoring systems for 24/7 protection. With audible and visual alarms for high/low temperature, door ajar, power failure, and sensor errors, you’ll have complete confidence in your cold chain integrity.
Designed for real-world pharmacy environments, the PH-ABT-VS-23G features durable powder coated steel construction with high-density urethane foam insulation and a self-closing glass door that maintains consistent temperatures even during frequent access. The six adjustable shelves accommodate various medication sizes while swivel casters with locking front wheels allow easy cleaning and repositioning. Safety-shielded LED lighting illuminates contents clearly, and the included pharmacy toolkit provides everything needed for optimal operation. With a 2-year comprehensive warranty and 7-year compressor coverage, the PH-ABT-VS-23G delivers reliable performance you can count on.
Key Features
• 23 cubic foot capacity optimized for pharmacy storage needs
• Maintains 2°C to 8°C with ±0.3°C stability using simulator probe
• Variable speed compressor with eco-friendly R600a refrigerant
• Digital microprocessor controller with remote alarm contacts
• ENERGY STAR® v2.0 qualified with under 1.2 KWh/day consumption
• ETL and C-ETL listed for safety and performance assurance
Benefits
• Reduce energy costs significantly with industry-leading efficiency under 1.2 KWh/day
• Ensure medication safety with precise ±1.5°C temperature control throughout cabinet
• Minimize disruption with whisper-quiet 40 dBA operation in patient care areas
• Maximize storage flexibility using six shelves adjustable in half-inch increments
• Protect inventory 24/7 with comprehensive alarms and remote monitoring capability
• Save space with compact 26.875″ width while maintaining 23 cubic feet capacity
• Enjoy peace of mind with 7-year compressor warranty backing your investment
• Maintain compliance easily with included NIST traceable calibration certificate
Description
| Storage capacity (cu. ft) | 23 Cu. Ft. |
| Door | One (1) swing glass door, self-closing, right hinged, not reversible, magnetic door gasket |
| Shelves | Six (6) adjustable shelves (adjustable in ½” increments) |
| Mounting and Installation | Swivel casters – locking front casters |
| External probe access | 3/4″ probe access port on rear wall |
| Insulation | Cabinet is foamed-in-place with EPA compliant high-density urethane foam |
| Interior lighting | LED interior lights are safety shielded and switch controlled |
| Airflow Management | Forced draft air circulation, patented air flow technology |
| Exterior materials | Cabinet is foamed-in-place with EPA compliant high-density urethane foam |
| Access control | Keyed door lock; compatible with optional digital lock (Pyxis, Omnicell, and AcuDose RX) |
| General warranty | Two (2) year parts and labor warranty |
| Compressor warranty | Seven (7) year compressor warranty |
| Product Weight (lbs) | 274 |
| Shipping Weight (lbs) | 327 |
| Rated Amperage | 3 Amps |
| Power Plug/Power Cord | NEMA 5-15 plug, vaccine storage power cord warning label |
| Facility Electrical Requirement | 110 – 120V AC, 15A breaker, NEMA 5-15 receptacle |
| Agency Listing and Certification | ETL, C-ETL listed. Meets or exceeds ENERGY STAR® v2.0 for Laboratory Refrigerators. Official listing pending – see energystar.gov |
Performance
| Maximum temperature variation (Cabinet air) | +/- 1.5° C |
| Stability (Cabinet air) | +/- 0.3° C |
| Energy Consumption (kWh/day) | <1.2 KWh/day *meets ENERGY STAR® v2.0 for Laboratory Refrigerators |
| Average Heat Rejection (BTU/hr) | <320 BTU/h |
| Pull down time to nominal operating temp | < 35 min (empty) |
| Noise Pressure Level (dBA) | 40 dBA or less installed |
| Compressor | Hermetic, variable speed |
| Refrigerant | EPA SNAP compliant R600a Isobutane (Hydrocarbon natural refrigerant) |
| Condenser | Tube and grid, high efficiency fan forced air |
| Evaporator | Fin and tube, high efficiency fan forced air |
| Defrost | Cycle Defrost |
| Performance Notes | Max temperature variation based on an empty chamber at steady state using 15 bare (unweighted) thermocouple probes. Product loading, door openings, and ambient conditions will affect performance. Stability of simulator ballast based on bottle probe provided with the unit located center of empty chamber at steady state, no door openings |
Temp Controller
| Controller technology | Microprocessor with color touchscreen (8in) input and display, C°/F° switchable, resolution is 0.1° C/0.2° F |
| Battery Backup | For controller temperature display and alarms only, no cooling active |
| Display technology | Digital temperature display |
| Adjustable Temperature Range | 36°F to 46°F (2°C to 8°C) Calibrated using a NIST traceable device, certificate included |
| Digital Communication | Non-applicable |
| External alarm connection | Remote alarm contacts |
| Alarms | Audible and visual high/low temperature alarms, remote alarm contacts, sensor error alarm, power failure alarm, door ajar alarm |
| Display Probe | Product simulator bottle with glass bead media |
| Included Accessories | Pharmacy refrigerator/freezer toolkit |
| Disclaimers | Refrigerator requires a minimum 2” of clearance around back and sides of the unit for proper ventilation (more if next to heat rejecting equipment) – improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure |
Product Documents