ABS 23 Cu. Ft. Premier Glass Door Laboratory Refrigerator ABT-VS-LP-23
American BioTech Supply 23 Cu. Ft. Premier Glass Door Laboratory Refrigerator ABT-VS-LP-23
The ABT-VS-LP-23 delivers exceptional temperature performance through advanced variable speed compressor technology and precise microprocessor control. With maximum temperature variation of just +/- 1.5°C in cabinet air and remarkable stability of +/- 0.3°C using simulator ballast, this 23 cubic foot laboratory refrigerator ensures your critical samples remain within strict parameters. The unitâs patented forced draft air circulation technology and EPA-compliant R600a hydrocarbon refrigerant combine to achieve ultra-low energy consumption of less than 1.2 KWh per day while meeting ENERGY STAR v2.0 standards.
Engineered for demanding clinical and research environments, the ABT-VS-LP-23 features comprehensive monitoring capabilities with audible and visual alarms for temperature excursions, sensor errors, power failures, and door ajar conditions. The digital temperature display offers C°/F° switchable readouts with 0.1°C resolution, while remote alarm contacts enable integration with facility monitoring systems. A keyed door lock provides immediate security, with compatibility for optional digital locks including Pyxis, Omnicell, and AcuDose RX systems.
Built to withstand continuous laboratory use, the ABT-VS-LP-23 combines a durable white powder-coated steel exterior with high-density urethane foam insulation for optimal efficiency. The self-closing glass door with magnetic gasket minimizes temperature fluctuations, while safety-shielded LED interior lighting and four adjustable shelves maximize usability. With swivel casters including locking front units for easy positioning, plus a generous 2-year parts and labor warranty backed by a 7-year compressor warranty, this premier refrigerator delivers long-term reliability for your most valuable specimens.
Key Features
- Variable speed compressor technology with microprocessor temperature control
- 23 cubic foot capacity with adjustable temperature range of 2°C to 15°C
- ENERGY STAR v2.0 compliant with <1.2 KWh/day energy consumption
- Four adjustable shelves with half-inch increment positioning
- ETL and C-ETL listed with 7-year compressor warranty
Benefits
- Achieve +/- 0.3°C stability to protect temperature-sensitive samples and reagents
- Reduce operating costs with ultra-low energy consumption and natural refrigerant
- Maintain compliance with comprehensive alarm system and remote monitoring capability
- Maximize storage flexibility with 23 cu ft capacity and adjustable shelving
- Ensure long-term reliability with 7-year compressor warranty coverage
- Integrate seamlessly with existing security systems via digital lock compatibility
Description
| Storage capacity (cu. ft) | 23 Cu. Ft. |
| Door | One (1) swing glass door, self-closing, right hinged, not reversible, magnetic door gasket |
| Shelves | Four (4) adjustable shelves (adjustable in ω increments) |
| Mounting and Installation | Swivel casters â locking front casters |
| External probe access | 3/4âł probe access port on rear wall |
| Insulation | Cabinet is foamed-in-place with EPA compliant high-density urethane foam |
| Interior lighting | LED interior lights are safety shielded and switch controlled |
| Airflow Management | Forced draft air circulation, patented air flow technology |
| Exterior materials | Cabinet is foamed-in-place with EPA compliant high-density urethane foam |
| Access control | Keyed door lock; compatible with optional digital lock (Pyxis, Omnicell, and AcuDose RX) |
| General warranty | Two (2) year parts and labor warranty |
| Compressor warranty | Seven (7) year compressor warranty |
| Product Weight (lbs) | 274 |
| Shipping Weight (lbs) | 327 |
| Rated Amperage | 3 Amps |
| Power Plug/Power Cord | NEMA 5-15 plug |
| Facility Electrical Requirement | 110 â 120V AC, 15A breaker, NEMA 5-15 receptacle |
| Agency Listing and Certification | ETL, C-ETL listed. Meets or exceeds ENERGY STARÂź v2.0 for Laboratory Refrigerators. Official listing pending â see energystar.gov |
Performance
| Maximum temperature variation (Cabinet air) | +/- 1.5° C |
| Stability (Simulator ballast) | +/- 0.3° C |
| Energy Consumption (kWh/day) | <1.2 KWh/day *meets ENERGY STARŸ v2.0 for Laboratory Refrigerators |
| Average Heat Rejection (BTU/hr) | <320 BTU/h |
| Pull down time to nominal operating temp | < 35 min (empty) |
| Noise Pressure Level (dBA) | 40 dBA or less installed |
| Compressor | Hermetic, variable speed |
| Refrigerant | EPA SNAP compliant R600a Isobutane (Hydrocarbon natural refrigerant) |
| Condenser | Tube and grid, high efficiency fan forced air |
| Evaporator | Fin and tube, high efficiency fan forced air |
| Defrost | Cycle Defrost |
| Performance Notes | Max temperature variation based on an empty chamber at steady state using 15 bare (unweighted) thermocouple probes. Product loading, door openings, and ambient conditions will affect performance. Stability of simulator ballast based on bottle probe provided with the unit located center of empty chamber at steady state, no door openings |
Temp Controller
| Controller technology | Microprocessor with color touchscreen (8in) input and display, C°/F° switchable, resolution is 0.1° C/0.2° F |
| Battery Backup | For controller temperature display and alarms only, no cooling active |
| Display technology | Digital temperature display |
| Adjustable Temperature Range | 2° C to 15° C |
| Digital Communication | Non-applicable |
| External alarm connection | Remote alarm contacts |
| Alarms | Audible and visual high/low temperature alarms, remote alarm contacts, sensor error alarm, power failure alarm, door ajar alarm |
| Display Probe | Product simulator bottle with glass bead media |
| Disclaimers | Refrigerator requires a minimum 2â of clearance around back and sides of the unit for proper ventilation (more if next to heat rejecting equipment) â improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure |
Â
Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
American BioTech Supply 23 Cu. Ft. Premier Glass Door Laboratory Refrigerator ABT-VS-LP-23
The ABT-VS-LP-23 delivers exceptional temperature performance through advanced variable speed compressor technology and precise microprocessor control. With maximum temperature variation of just +/- 1.5°C in cabinet air and remarkable stability of +/- 0.3°C using simulator ballast, this 23 cubic foot laboratory refrigerator ensures your critical samples remain within strict parameters. The unitâs patented forced draft air circulation technology and EPA-compliant R600a hydrocarbon refrigerant combine to achieve ultra-low energy consumption of less than 1.2 KWh per day while meeting ENERGY STAR v2.0 standards.
Engineered for demanding clinical and research environments, the ABT-VS-LP-23 features comprehensive monitoring capabilities with audible and visual alarms for temperature excursions, sensor errors, power failures, and door ajar conditions. The digital temperature display offers C°/F° switchable readouts with 0.1°C resolution, while remote alarm contacts enable integration with facility monitoring systems. A keyed door lock provides immediate security, with compatibility for optional digital locks including Pyxis, Omnicell, and AcuDose RX systems.
Built to withstand continuous laboratory use, the ABT-VS-LP-23 combines a durable white powder-coated steel exterior with high-density urethane foam insulation for optimal efficiency. The self-closing glass door with magnetic gasket minimizes temperature fluctuations, while safety-shielded LED interior lighting and four adjustable shelves maximize usability. With swivel casters including locking front units for easy positioning, plus a generous 2-year parts and labor warranty backed by a 7-year compressor warranty, this premier refrigerator delivers long-term reliability for your most valuable specimens.
Key Features
- Variable speed compressor technology with microprocessor temperature control
- 23 cubic foot capacity with adjustable temperature range of 2°C to 15°C
- ENERGY STAR v2.0 compliant with <1.2 KWh/day energy consumption
- Four adjustable shelves with half-inch increment positioning
- ETL and C-ETL listed with 7-year compressor warranty
Benefits
- Achieve +/- 0.3°C stability to protect temperature-sensitive samples and reagents
- Reduce operating costs with ultra-low energy consumption and natural refrigerant
- Maintain compliance with comprehensive alarm system and remote monitoring capability
- Maximize storage flexibility with 23 cu ft capacity and adjustable shelving
- Ensure long-term reliability with 7-year compressor warranty coverage
- Integrate seamlessly with existing security systems via digital lock compatibility
Description
| Storage capacity (cu. ft) | 23 Cu. Ft. |
| Door | One (1) swing glass door, self-closing, right hinged, not reversible, magnetic door gasket |
| Shelves | Four (4) adjustable shelves (adjustable in ω increments) |
| Mounting and Installation | Swivel casters â locking front casters |
| External probe access | 3/4âł probe access port on rear wall |
| Insulation | Cabinet is foamed-in-place with EPA compliant high-density urethane foam |
| Interior lighting | LED interior lights are safety shielded and switch controlled |
| Airflow Management | Forced draft air circulation, patented air flow technology |
| Exterior materials | Cabinet is foamed-in-place with EPA compliant high-density urethane foam |
| Access control | Keyed door lock; compatible with optional digital lock (Pyxis, Omnicell, and AcuDose RX) |
| General warranty | Two (2) year parts and labor warranty |
| Compressor warranty | Seven (7) year compressor warranty |
| Product Weight (lbs) | 274 |
| Shipping Weight (lbs) | 327 |
| Rated Amperage | 3 Amps |
| Power Plug/Power Cord | NEMA 5-15 plug |
| Facility Electrical Requirement | 110 â 120V AC, 15A breaker, NEMA 5-15 receptacle |
| Agency Listing and Certification | ETL, C-ETL listed. Meets or exceeds ENERGY STARÂź v2.0 for Laboratory Refrigerators. Official listing pending â see energystar.gov |
Performance
| Maximum temperature variation (Cabinet air) | +/- 1.5° C |
| Stability (Simulator ballast) | +/- 0.3° C |
| Energy Consumption (kWh/day) | <1.2 KWh/day *meets ENERGY STARŸ v2.0 for Laboratory Refrigerators |
| Average Heat Rejection (BTU/hr) | <320 BTU/h |
| Pull down time to nominal operating temp | < 35 min (empty) |
| Noise Pressure Level (dBA) | 40 dBA or less installed |
| Compressor | Hermetic, variable speed |
| Refrigerant | EPA SNAP compliant R600a Isobutane (Hydrocarbon natural refrigerant) |
| Condenser | Tube and grid, high efficiency fan forced air |
| Evaporator | Fin and tube, high efficiency fan forced air |
| Defrost | Cycle Defrost |
| Performance Notes | Max temperature variation based on an empty chamber at steady state using 15 bare (unweighted) thermocouple probes. Product loading, door openings, and ambient conditions will affect performance. Stability of simulator ballast based on bottle probe provided with the unit located center of empty chamber at steady state, no door openings |
Temp Controller
| Controller technology | Microprocessor with color touchscreen (8in) input and display, C°/F° switchable, resolution is 0.1° C/0.2° F |
| Battery Backup | For controller temperature display and alarms only, no cooling active |
| Display technology | Digital temperature display |
| Adjustable Temperature Range | 2° C to 15° C |
| Digital Communication | Non-applicable |
| External alarm connection | Remote alarm contacts |
| Alarms | Audible and visual high/low temperature alarms, remote alarm contacts, sensor error alarm, power failure alarm, door ajar alarm |
| Display Probe | Product simulator bottle with glass bead media |
| Disclaimers | Refrigerator requires a minimum 2â of clearance around back and sides of the unit for proper ventilation (more if next to heat rejecting equipment) â improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure |
Â