ABS 12 Cu. Ft. Standard Pharmacy Glass Door Refrigerator PH-ABT-VS-S12G
ABS 12 Cu. Ft. Standard Pharmacy Glass Door Refrigerator PH-ABT-VS-S12G
These pharmacy refrigerators are designed for reliable and cost-effective cold storage. This model features ultra-low energy consumption and energy efficient natural refrigerants. Using microprocessor temperature technology, this unit delivers precise temperature monitoring and control. It offers essential security features, including a keyed door lock and temperature alarms, along with remote alarm contacts. Enjoy durable powder-coated steel construction, glass door transparency, and adjustable inner shelving to optimize your workflow. All features are designed to heighten performance and efficiency in your clinical setting.
Details
| Storage capacity | 12 Cu. Ft. | ||
| Door | One (1) swing glass door, self-closing, right hinged, not reversible, magnetic door gasket | ||
| Shelves | Three (3) adjustable shelves (adjustable in ½ā increments) | ||
| Drawers | Non-applicable | ||
| Mounting and Installation | Swivel casters ā locking front casters | ||
| Interior lighting | LED interior lights are safety shielded and switch controlled | ||
| Airflow Management | Forced draft air circulation ā Patented air flow technology | ||
| External probe access | Probe access port (3/4ā³) on rear wall | ||
| Insulation | Cabinet is foamed-in-place with EPA compliant high density urethane foam | ||
| Exterior materials | White powder coated steel | ||
| Access control | Keyed door lock; compatible with optional digital lock (including Pyxis, Omnicell, and AcuDose RX) | ||
| General warranty | Two (2) year parts and labor warranty | ||
| Compressor warranty | Five (5) year compressor warranty | ||
| Product Weight (lbs) | 221 | ||
| Shipping Weight (lbs) | 254 | ||
| Exterior Width (in) | 25ā³ | ||
| Exterior Depth (in) | 29ā³ | ||
| Exterior Height (in) | 66ā³ | ||
| Rated Amperage | 2 Amps | ||
| Power Plug/Power Cord | NEMA 5-15 plug, vaccine storage power cord warning label | ||
| Facility Electrical Requirement | 110 ā 120V AC, 15A breaker, NEMA 5-15 receptacle | ||
| Agency Listing and Certification | ETL, C-ETL listed. Meets or exceeds Energy Star v2.0 for Laboratory Refrigerators. Official listing pending ā see energystar.gov | ||
Refrigeration System
| Compressor | Hermetic | ||
| Refrigerant | EPA SNAP compliant R600a Isobutane (Hydrocarbon natural refrigerant) | ||
| Condenser | Tube and grid, high efficiency fan forced air | ||
| Evaporator | Fin and tube, high efficiency fan forced air | ||
| Defrost | Cycle defrost | ||
Temp Controller
| Controller technology | Microprocessor temperature controller, C°/F° switchable, resolution is 0.1° C/0.2° F | ||
| Noise pressure levelĀ Ā (dBA) | 40 dBA or less installed | ||
| Display technology | Ā Digital Temperature Display | ||
| Stability ā simulatorĀ Ā ballast (°C) | +/- 0.5° C | ||
| Average heat rejection (BTU/h) | < 250 BTU/h | ||
| Max temp variation ā cabinet air (°C) | +/- 2.5° C | ||
| Adjustable Temperature Range | 36° F to 46° F (2° C to 8° C), Calibrated using a NIST traceable device, certificate included | ||
| External alarmĀ Ā connection | Remote alarm contacts | ||
| Included accessories | Pharmacy refrigerator/freezer toolkit | ||
| Battery Backup | For controller temperature display and alarms only, no cooling active | ||
| Energy consumption (KWh/day) | <0.9 KWh/day *meets Energy Star v2.0 for Laboratory Refrigerators | ||
| Display probe | Product simulator bottle with glass bead media | ||
| Pull down time to nominal operatingĀ Ā temp | < 30 min (empty) | ||
| Alarms | Audible and visual high/low temperature alarms, remote alarm contacts | ||
| Disclaimer(s): | Refrigerator requires a minimum 2ā of clearance at back and sides of the unit for proper ventilation | ||
| Performance Note | Max temperature variation based on an empty chamber at steady state using 15 bare (unweighted) thermocouple probes. Product loading, door openings, and ambient conditions will affect performance. Stability of simulator ballast based on bottle probe provided with the unit located center of empty chamber at steady state, no door openings | ||
Ā
Original: $2,778.00
-65%$2,778.00
$972.30Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
ABS 12 Cu. Ft. Standard Pharmacy Glass Door Refrigerator PH-ABT-VS-S12G
These pharmacy refrigerators are designed for reliable and cost-effective cold storage. This model features ultra-low energy consumption and energy efficient natural refrigerants. Using microprocessor temperature technology, this unit delivers precise temperature monitoring and control. It offers essential security features, including a keyed door lock and temperature alarms, along with remote alarm contacts. Enjoy durable powder-coated steel construction, glass door transparency, and adjustable inner shelving to optimize your workflow. All features are designed to heighten performance and efficiency in your clinical setting.
Details
| Storage capacity | 12 Cu. Ft. | ||
| Door | One (1) swing glass door, self-closing, right hinged, not reversible, magnetic door gasket | ||
| Shelves | Three (3) adjustable shelves (adjustable in ½ā increments) | ||
| Drawers | Non-applicable | ||
| Mounting and Installation | Swivel casters ā locking front casters | ||
| Interior lighting | LED interior lights are safety shielded and switch controlled | ||
| Airflow Management | Forced draft air circulation ā Patented air flow technology | ||
| External probe access | Probe access port (3/4ā³) on rear wall | ||
| Insulation | Cabinet is foamed-in-place with EPA compliant high density urethane foam | ||
| Exterior materials | White powder coated steel | ||
| Access control | Keyed door lock; compatible with optional digital lock (including Pyxis, Omnicell, and AcuDose RX) | ||
| General warranty | Two (2) year parts and labor warranty | ||
| Compressor warranty | Five (5) year compressor warranty | ||
| Product Weight (lbs) | 221 | ||
| Shipping Weight (lbs) | 254 | ||
| Exterior Width (in) | 25ā³ | ||
| Exterior Depth (in) | 29ā³ | ||
| Exterior Height (in) | 66ā³ | ||
| Rated Amperage | 2 Amps | ||
| Power Plug/Power Cord | NEMA 5-15 plug, vaccine storage power cord warning label | ||
| Facility Electrical Requirement | 110 ā 120V AC, 15A breaker, NEMA 5-15 receptacle | ||
| Agency Listing and Certification | ETL, C-ETL listed. Meets or exceeds Energy Star v2.0 for Laboratory Refrigerators. Official listing pending ā see energystar.gov | ||
Refrigeration System
| Compressor | Hermetic | ||
| Refrigerant | EPA SNAP compliant R600a Isobutane (Hydrocarbon natural refrigerant) | ||
| Condenser | Tube and grid, high efficiency fan forced air | ||
| Evaporator | Fin and tube, high efficiency fan forced air | ||
| Defrost | Cycle defrost | ||
Temp Controller
| Controller technology | Microprocessor temperature controller, C°/F° switchable, resolution is 0.1° C/0.2° F | ||
| Noise pressure levelĀ Ā (dBA) | 40 dBA or less installed | ||
| Display technology | Ā Digital Temperature Display | ||
| Stability ā simulatorĀ Ā ballast (°C) | +/- 0.5° C | ||
| Average heat rejection (BTU/h) | < 250 BTU/h | ||
| Max temp variation ā cabinet air (°C) | +/- 2.5° C | ||
| Adjustable Temperature Range | 36° F to 46° F (2° C to 8° C), Calibrated using a NIST traceable device, certificate included | ||
| External alarmĀ Ā connection | Remote alarm contacts | ||
| Included accessories | Pharmacy refrigerator/freezer toolkit | ||
| Battery Backup | For controller temperature display and alarms only, no cooling active | ||
| Energy consumption (KWh/day) | <0.9 KWh/day *meets Energy Star v2.0 for Laboratory Refrigerators | ||
| Display probe | Product simulator bottle with glass bead media | ||
| Pull down time to nominal operatingĀ Ā temp | < 30 min (empty) | ||
| Alarms | Audible and visual high/low temperature alarms, remote alarm contacts | ||
| Disclaimer(s): | Refrigerator requires a minimum 2ā of clearance at back and sides of the unit for proper ventilation | ||
| Performance Note | Max temperature variation based on an empty chamber at steady state using 15 bare (unweighted) thermocouple probes. Product loading, door openings, and ambient conditions will affect performance. Stability of simulator ballast based on bottle probe provided with the unit located center of empty chamber at steady state, no door openings | ||
Ā